<LOGO>
FM Transmitter Measurement Report
Created: 2023-02-26 02-37-39
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.20 MHz 4/5, 42 dBuV INTER
Pilot RDS Phase Difference
7.3 kHz 2.3 kHz 53 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 12 kHz 11501 0,5826
Modulation Power
Limit Measuring Tolerance
9,0 dBr 0,0 dBr
MIN AVE MAX % above 9,0 dBr
0,9 dBr 3,17 dBr 5,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INTER " F201 0 (No PTY) 1 0 1 1 2:37, 26.02.2023
RT
"EN MARGE - NICOLAS MAURY INCASSABLE - FRANCE INTER 1ERE RADIO "
AF EON
87.8, 88.1, 92.6, 93.0, 93.2, 93.8, 94.6, 94.9, 95.0, 95.1, 96.3, 96.5, 96.8, 99.2, 99.4, 99.5, 99.6, 99.9, 100.2, 100.7, 101.9 MHz F209, F202, F206, F203
FM Scope Station: 100.20 MHz, signal: 4/5 (42 dBuV) Max at: 12 kHz MIN: 11 kHz % above 75 kHz: 0,5826 Acquired: 2023/02/26 2:36:35 Total samples: 11501 Equivalent time: 0:09:35 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 5,3 dBr MIN: 0,9 dBr AVE: 3,17 dBr % above 9,0 dBr: 0,0 Last value: 3,4 dBr (2023/02/26 2:36:33) Station: 100.20 MHz, signal: 4/5 (42 dBuV) 02:24 02:26 02:28 02:30 02:32 02:34 02:36 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality